Overall Experience
Quality
Price
Convenience
Shalik was careful and thorough. Very polite & pleasant to deal with. Everything left tidy and in order!
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Wes did a thorough investigation of our furnace issue and ordered the needed parts.
Overall Experience
Quality
Price
Convenience
Evans called my tenant and made after hours appointment with out stating that there was a $60 fee for an after hours appointment. The tenant would have been ok with waiting until Tuesday.
Overall Experience
Quality
Price
Convenience
Couldn’t have asked for a better technician. Shalik was a joy to have in our house.
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Shalik was very thorough and friendly Awesome job
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Technician arrived on time. Friendly and knowledgeable. Worked quickly and efficiently and made me aware of issues he found. Estimates to repair are being supplied.
Overall Experience
Quality
Price
Convenience
Andrew was on time, polite, efficient and thorough. I will definitely use this company for further service for my furnace and air conditioner l
Overall Experience
Quality
Price
Convenience
Good service. He explained everything clearly. Nice guy to deal with. Very professional.
Overall Experience
Quality
Price
Convenience
The technician was friendly and did a great job, we are very pleased all round! 😀
Overall Experience
Quality
Price
Convenience
Service Type: Furnace Maintenance Equipment: 2016 Luxaire High-Efficiency Furnace (Builder Model) Inspection & Findings: - Completed full furnace maintenance. - Furnace is operating normally at this time. - Found a small leak at the exterior PVC venting connection. - Repair requires replacement of: - PVC tee - 1/2" to 3/4" barbed PVC adapter - PVC 90 - PVC coupling - Quoted $96 for PVC drain repair. - Client is currently mitigating the small drip. Venting & Moisture Concerns: - Air intake is positioned directly above the gas valve. - During warmer months, condensate drips onto the gas valve and burners. - Rust observed forming on the gas valve and burners. - Concern for burner deterioration over time if mitigation is not performed. - Recommend adding a vent drain diverter and relocating the air intake to the left side of the furnace to prevent ongoing moisture exposure. Burners & Electrical: - Burners showing signs of rust; longevity is a concern. - Client requested verific
Service Type: Furnace Maintenance Equipment: 2004 Lennox High-Efficiency Furnace Inspection & Findings: - Completed furnace maintenance. - Inducer motor remains loud and vibrating; condition noted during last year’s maintenance as well. - Older ABS venting inspected and found to be in fair condition; advised regular inspection for cracks or leaks. - Humidifier operating normally. - Burners showing rust and age-related deterioration. - Ignitor resistance reading measured low at approximately 17 ohms, indicating wear; ignitor may not last. - OEM ignitor required for this unit. - Combustion analysis performed and results are within acceptable range. Blower wheel inspected and found coated in dust and debris. May be hindering performance. Small water leak from exhaust drain diverter left hand side(exhaust is right) Recommendations: - Recommend replacing inducer motor due to noise and vibration. - Recommend replacing burners due to rusting and risk of burner port restriction and shutdow
Furnace Maintenance: Replaced homeowner provided media filter (16x25x1) and added orientation arrows for proper set up. Furance was not engaging into second stage gas changed the pin P5 from none to 10. Flushed the condensate P-trap and drain lines to maintain clear, efficient flow. Checked pressure switch tubing to ensure reliable performance. Cleaned and polished the flame sensor for optimal ignition. Ran full diagnostics to confirm the system is running smoothly and efficiently. Andy and Patel Happy Holidays
Fireplace maintenance Cleaned and inspected unit Cleared blockage from pilot tube Tested all electrical components Tested remote functions No problems found. Unit is running safely.
Install bypass humidifier and test. Operating normally
Furnace repair Replaced pressure switch and ensured unit operation. No other problems found on unit.
Furnace Maintenance: Homeowner says the furnace had been intermittent twice, inspected and reconnected thermostat wiring. Checked error codes (271, 227). Quoting out pressure switch. Inspected flue Termination for any build up and found plant growing into intake. Flushed the condensate P-trap and drain lines to maintain clear, efficient flow. Checked pressure switch tubing to ensure reliable . Cleaned and polished the flame sensor for optimal ignition. Ran full diagnostics to confirm the system is running smoothly and efficiently. 271 - Soft Lock out, No flame sensed. 227 - Low Pressure Switch Open during trial for ignition.
Fireplace Maintenance: Thoroughly cleaned the firebox, removing soot, dust, debris, and any pests. Vacuumed and dusted the ceramic log set, restoring its polished appearance. Inspected wiring to confirm secure connections and overall safety. Cleaned and polished the viewing glass using a specialized fireplace glass cleaner for optimal clarity. Conducted a detailed cleaning of the pilot assembly to ensure reliable performance.
Furnace Maintenance: Inspected Humidifier damper door to insure it was open. Put a quote out for the humifer drain spud. Replaced the furnace filter with 1056. Flushed the condensate P-trap and drain lines to maintain clear, efficient flow. Checked pressure switch tubing to ensure reliable performance. Cleaned and polished the flame sensor for optimal ignition. Ran full diagnostics to confirm the system is running smoothly and efficiently.
Furnace Maintenance: Addressed leak by adding 90 fitting and clamp. Flushed the condensate P-trap and drain lines to maintain clear, efficient flow. Checked pressure switch tubing to ensure reliable performance. Cleaned and polished the flame sensor for optimal ignition. Ran full diagnostics to confirm the system is running smoothly and efficiently.
Furnace Maintenance: Replaced media filter with x6670 (16x25x5). Flushed the condensate P-trap and drain lines to maintain clear, efficient flow. Checked pressure switch tubing to ensure reliable performance. Cleaned and polished the flame sensor for optimal ignition. Ran full diagnostics to confirm the system is running smoothly and efficiently
Furnace Maintenance: Replaced media filter (16x25x1 [used last filter, will need to pick up more]. Cleaned and Confirmed air cleaner is working. Blower wheel has a bit of build up, recommend having it cleaned in thw near future for airflow optimization. Humidifier is not working. Flushed the condensate P-trap and drain lines to maintain clear, efficient flow. Checked pressure switch tubing to ensure reliable performance. Cleaned and polished the flame sensor for optimal ignition. Ran full diagnostics to confirm the system is running smoothly and efficiently.
Furnace service call Originally sent for igniter but found pressure switch not closing. Replaced switch. Furnace works as normal operation. No other problems found at this time.